Six Comprehensive Cabling Considerations for Parking Management Systems
2022-05-16
The six wiring aspects of a parking management system should pay attention to the following six points:
1. Place the controller in a concealed or secure location to prevent deliberate vandalism. Indoor wiring must not only be safe and reliable but also properly routed, neatly arranged, and securely fastened.
2. The rated voltage of the conductors used shall be greater than the operating voltage of the circuit; the insulation of the conductors shall comply with the circuit installation method and the environmental conditions of the installation location. The cross-sectional area of the conductors shall meet the requirements for power supply and mechanical strength.
3. In structured cabling, wire splices should be avoided as much as possible. Unless a splice is absolutely necessary, it must be securely crimped or soldered and made waterproof. Wire connections and branch points shall not be subjected to mechanical stress.

4. Wiring shall be installed horizontally or vertically within the building. All connections must be protected by conduit (plastic or galvanized steel pipe, selected in accordance with indoor wiring technical requirements). For ceiling wiring, metal flexible conduit or PVC conduit may be used, provided that the installation is secure and aesthetically pleasing.
5. Signal cables shall not be routed parallel to high-power power cables, nor shall they be routed through conduits. If, due to environmental constraints, parallel routing is unavoidable, the separation distance shall exceed 50 centimeters.
6. The AC power supply for the control cabinet shall be wired separately and shall not be routed in the same conduit as signal cables or low-voltage DC power cables. The installation of the AC power cables shall comply with electrical installation standards.
Wiring from the control cabinet to the ceiling shall be routed through waterproof conduit embedded in the wall or through hot-dip galvanized steel pipe, with comprehensive protective measures implemented to enhance the damage-resistance of the intrusion alarm system.
Regarding network equipment, COLORAPUS It has a seamless chain (from network cables to optical cables to data centers), establishing an end-to-end marketing and after-sales service operation system in China. Kolorapus has passed the ISO9001 (2008) quality management system certification. It has developed more than six types of UTP Cat.6A shielded cabling systems that meet the needs of big data centers, and has also passed quality inspection certifications from multiple testing agencies. It has set up liaison offices and sales offices for its own brand in countries such as the United States, Europe, Malaysia, Switzerland, Germany, the Middle East, and South Africa, and provides OEM services in more than 30 countries and regions, delivering globalized product services.
Kolorapus is a solution that integrates copper cable wiring, optical cable wiring, and intelligent electronic wiring racks, Data Center MTP/MPO High-Density Solution It is a high-tech enterprise integrating independent R&D, design, production, and sales of products such as data center cold aisle solutions, eight copper cable solutions for data centers, secure cables, and intelligent management wiring system platforms. The company is user-demand oriented and provides customers with attractive OCASTR products. Kolorapus cabling in four colors is convenient!